JUMO mTRON T
Measuring, Control, and Automation System
Digital Input/Output Module 12-Channel
B 705030.0
Operating Manual
2014-01-20/00575632
Zobrazit stránku 0
1 2 3 4 5 6 ... 49 50

Shrnutí obsahu

Strany 1 - JUMO mTRON T

JUMO mTRON TMeasuring, Control, and Automation SystemDigital Input/Output Module 12-ChannelB 705030.0Operating Manual2014-01-20/00575632

Strany 2

1 Introduction101.3.4 DisposalDisposing of the deviceDisposing of the packaging materialThe entire packaging material (cardboard packaging, inserts, p

Strany 3 - Contents

111 Introduction1.4 Identifying the Device Version1.4.1 NameplatesPositionThe nameplate (B) is affixed to the module case.An additional nameplate with

Strany 4

1 Introduction12Fabrication no. (F-Nr)Among other things, the fabrication number contains the date of production (year/week).Example: F-Nr = 007003380

Strany 5

132 Description2.1 Brief descriptionThe module is equipped with 12 channels which can optionally be configured as digital inputsor digital outputs.The

Strany 6

2 Description14

Strany 7

153 Mounting3.1 General information on installation/dismountingMounting siteAll modules have protection type IP20 and are only intended for use in fir

Strany 8

3 Mounting16Minimum distances3.2 Installation/dismounting on DIN railAll modules in the system are intended for installation on a DIN rail according t

Strany 9

173 MountingInstallation, using the example of a multichannel controller module 705010Example installationProcedure:(A) (A1)(A2)Step Activity1 Mount t

Strany 10 - 1 Introduction

3 Mounting18Dismounting, using the example of a multichannel controller module 705010Removing the multichannel controller module from the DIN railProc

Strany 11

193 Mounting3 Move the modules (B) on the right next to the multichannel controller module that is to be replaced (A) a minimum of 20 mm to the right

Strany 13 - 2 Description

3 Mounting203.3 Replacing module inserts3.3.1 Input/output modulesReplacement of a module insert, using the example of a multichannel controller modul

Strany 14

213 MountingRemoving the module insertMounting the module insertCAUTION!Only module inserts of the same type may be used for the replacement.Otherwise

Strany 15 - 3 Mounting

3 Mounting223.4 Dimensions22.5103.66.610194.5101.517.6

Strany 16

234 Electrical connection4.1 Installation notesRequirements for the personnel• Work on the modules must only be carried out to the extent described an

Strany 17

4 Electrical connection24References to other information• The electromagnetic compatibility meets the standards and regulations cited in the techni-ca

Strany 18

254 Electrical connection4.3.1 Display and connection elementsCAUTION!Signals to the several digital inputs must have the same ground reference.Otherw

Strany 19

4 Electrical connection264.3.2 Digital input The connection depends on the configuration (input or output).4.3.3 Digital outputsThe connection depends

Strany 20

274 Electrical connection4.4 Functional testThe voltage supply must be tested on completion of the electrical connection:StartupThe check described ab

Strany 21

4 Electrical connection28

Strany 22

295 Operation5.1 Display and connection elements(1) Status displays (LED)P = Voltage supplyS = Status1 to 12 = Digital input/output(LED is lit: Active

Strany 23 - 4 Electrical connection

3Contents1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51.1 Available tec

Strany 24

5 Operation305.2 LED displays"P" LED (Power)The LED is permanently lit in green if the module is being supplied with voltage."S" L

Strany 25

315 Operation5.2.2 System states and errorsThe following table lists all the system states and errors that are indicated by the "S" LED (Sta

Strany 26

5 Operation32

Strany 27

336 Configuration6.1 Digital inputs/outputsThe digital input/output module has 12 channels, each of which can be configured as digitalinput or digital

Strany 28

6 Configuration34Level at suppressionWhen signal suppression is active, the input signal and the inverting parameter are irrelevant.In this case, a fi

Strany 29 - 5 Operation

356 Configuration6.1.1 AlarmSignal monitoring can be activated for each digital input. Setup dialogParametersEvent textSetup program: Selection of tex

Strany 30

6 Configuration366.2 NV connecting listThe NV connecting list is used to link external inputs (NV_...) of the digital input/output moduleto signals fr

Strany 31

376 ConfigurationReplacement valueThe replacement value is used if the relevant signal is not available (connection to base unitinterrupted or system

Strany 32

6 Configuration38Programgenerator 1 toProgramgenerator 9Operating contact 1 to 16 Operating contact 1 to 16 of program channels (in the three program

Strany 33 - 6 Configuration

396 ConfigurationAlarms/FaultsCAlarm/Fault System collective alarm or system fault (cen-tral processing unit and modules)CAlarm/Fault ackn. System col

Strany 34

Contents44.4 Functional test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 35

6 Configuration40Multichannel controller moduleController C01ManualMode to C04ManualModeManual mode active for controller channel 1to4C01TuneActive to

Strany 36

416 ConfigurationAnalog input module 4-channelAnalog inputs AI01Alarm1 to AI04Alarm1 Alarm signal 1 of analog input 1 to 4AI01Alarm2 to AI04Alarm2 Ala

Strany 37

6 Configuration426.2.2 Replacement values (overview)The following table contains the replacement values with their factory settings. Replacementvalues

Strany 38

437 Online parameters7.1 Calibrate / test7.1.1 Digital outputSetup dialogParametersNOTE!An active connection between the setup program and the central

Strany 39

7 Online parameters447.1.2 Digital inputSetup dialogParametersParameters Selection/settings DescriptionRead out Click the "Read out" button.

Strany 40

457 Online parameters7.1.3 VersionsSetup dialogThis dialog displays the module versions.

Strany 41

7 Online parameters46

Strany 42

478 Appendix8.1 Technical data8.1.1 Digital inputs and outputs8.1.2 Electrical dataNumber 12Digital inputsInput signal DC 0/24 V(PLC level; logical ”0

Strany 43 - 7 Online parameters

8 Appendix488.1.3 Case and ambient conditions8.1.4 Approval/approval marksCase type Plastic case for DIN rail mounting in the control cabinet (indoor

Strany 45

51 Introduction1.1 Available technical documentationThe documents specified below are available for the measuring, control, and automation sys-tem.1.1

Strany 46

JUMO GmbH & Co. KGStreet address:Moritz-Juchheim-Straße 136039 Fulda, GermanyDelivery address:Mackenrodtstraße 1436039 Fulda, GermanyPostal addres

Strany 47 - 8 Appendix

1 Introduction61.1.4 Special modules1.1.5 Operating, visualization, recording1.1.6 Power supply unitsProduct Type of documentation No. Printed PDF fil

Strany 48

71 Introduction1.2 Safety information1.2.1 Warning symbols1.2.2 Note signsDANGER!This symbol indicates that personal injury caused by electrical shock

Strany 49

1 Introduction81.2.3 Intended useThe modules described are intended for measuring, control, and automation tasks in an indus-trial environment, as des

Strany 50

91 Introduction1.3 Acceptance of goods, storage, and transport1.3.1 Checking the delivery• Ensure that the packaging and contents are not damaged • Ch